• Power Transmission Line Protection are used to intelligently identity safety hazards in power lines and communication fibers, as well as in teh surrounding environment. And it will automatically alarm to the online platform to notify workers to maintain. This greatly reduces the linklihood of accidents (reduce blackout and trip rates) and can replace manual inspections. DPS provide Low temperature battery module for intelligent monitoring and shooting device, the battery can be charged from -20 to 70℃, discharged from -40 to 70 . Currently, we have over 3000 batteries for Power Transmission Line Protection.

     

    broken image
    broken image
    broken image
    broken image

    Low Temperature LiFePo4 6.4V24Ah

    DPS-6.4V-24Ah

    Nominal Voltage:6.4V

    Nominal Capacity:24Ah

    Max Discharge Current:5A

    Max Charge Current:5A

    Discharge Cut-off Voltage:5V

    Charge Cut-off Voltage:7.3V

    Assembly Method:2S6P

    Charge Temperature Range: -20oC-55oC

    Discharge Temperature Range:-40oC-60oC

    The discharge capacity -40℃/25℃ ≥50%;-30℃/25℃ ≥70% ;-20℃/25℃ ≥80%

    broken image

    Low Temperature LiFePo4 6.4V36Ah

    DPS-6.4V-36Ah

    Nominal Voltage:6.4V

    Nominal Capacity:36Ah

    Max Discharge Current:5A

    Max Charge Current:5A

    Discharge Cut-off Voltage:5V

    Charge Cut-off Voltage:7.3V

    Assembly Method:2S9P

    Charge Temperature Range: -20-55℃

    Discharge Temperature Range:-40-60℃

    The discharge capacity -40℃/25℃ ≥50%;-30℃/25℃ ≥70% ;-20℃/25℃ ≥80%

    broken image

    Low Temperature LiFePo4 12.8V100Ah

    DPS-12.8V-100Ah

    Nominal Voltage:12.8V

    Max Discharge Current:30A

    Max Charge Current:30A

    Discharge Cut-off Voltage:10V

    Charge Cut-off Voltage:14.6V

    Assembly Method:4S25P

    Charge Temperature Range: -20-55℃

    Discharge Temperature Range:-40-60℃

    IP:67

    Battery case material:304 stainless steel

    Communication: RS485

    The discharge capacity -40℃/25℃ ≥50%;-30℃/25℃ ≥70% ;-20℃/25℃ ≥80%

    broken image

    Outdoor equipment battery pack

    DPS-3.6V-24.5Ah

    Nominal Voltage:3.6V

    Max Discharge Current:5A

    Max Charge Current:5A

    Discharge Cut-off Voltage:2.8V

    Charge Cut-off Voltage:4.2V

    Assembly Method:1S7P(18650 3.5Ah cell)

    Charge Temperature Range: 0-55℃

    Discharge Temperature Range:-40-60℃ 

    The discharge capacity -40℃/25℃ ≥50%;-30℃/25℃ ≥70% ;-20℃/25℃ ≥80%

    broken image

    Low temperature NMC-3.6V-7.0Ah

    DPS-3.6V-7.0Ah

    Nominal Voltage:3.6V

    Max Discharge Current:3A

    Max Charge Current:3A

    Discharge Cut-off Voltage:2.8V

    Charge Cut-off Voltage:4.2V

    Assembly Method:1S2P(18650 3.5Ah cell)

    Charge Temperature Range: 0-55℃

    Discharge Temperature Range:-40-60℃ 

    The discharge capacity -40℃/25℃ ≥50%;-30℃/25℃ ≥70% ;-20℃/25℃ ≥80%

    The pcba has the temperature sensor, you can use MCU read the battery temperature. The temperature R is 10KO, B value is 3380K

    broken image

    Low temperature NMC10.8V-35Ah with SMbus

    DPS-10.8V-35Ah

    Nominal Voltage:10.8V

    Max Discharge Current:10A

    Max Charge Current:10A

    Discharge Cut-off Voltage:8.25V

    Charge Cut-off Voltage:12.6VV

    Assembly Method:3S10P(18650 3.5Ah cell)

    Charge Temperature Range: -10-55℃

    Discharge Temperature Range:-40-60℃

    The discharge capacity -40℃/25℃ ≥50%;-30℃/25℃ ≥70% ;-20℃/25℃ ≥80%

    SMbus communication

    Advanced Charge Algorithm

     

    broken image

    wide temperature NMC10.8V-25Ah with SMbus

    DPS-10.8V-25Ah

    Nominal Voltage:10.8V

    Max Discharge Current:10A

    Max Charge Current:10A

    Discharge Cut-off Voltage:8.25V

    Charge Cut-off Voltage:12.6VV

    Assembly Method:3S10P(18650 2.5Ah cell)

    Charge Temperature Range: -20-70℃

    Discharge Temperature Range:-40-85℃

    The discharge capacity -40℃/25℃ ≥50%;-30℃/25℃ ≥70% ;-20℃/25℃ ≥80%